Zebra stripes on low-gloss profiles — what causes them?
Zebra stripes are alternating light and dark bands caused, in our field experience, by uneven film build along the profile. When reciprocator movement does not match conveyor speed, gun count and gun spacing, spray paths overlap in some areas and leave gaps in others. Low-gloss finishes show the resulting gloss change particularly clearly.
Moreaco is a powder coating manufacturer in Yunnan, China, specialising in custom and bonded metallic powder coatings.
Common causes
Reciprocator and conveyor mismatch
The gun movement and forward line speed do not create evenly spaced spray paths.
Spray paths overlap
Overlapping paths build a thicker film while gaps remain thinner.
Gun count or spacing is ignored
Reciprocator speed is adjusted by feel rather than from the actual line arrangement.
Low-gloss sensitivity
Small film-thickness differences can become visible as gloss bands.
How to check
- Record conveyor speed, reciprocator speed, number of guns and distance between guns.
- Map the wavy spray path of each gun and look for overlap or gaps.
- Measure film build and gloss in both the light and dark bands.
- Change one line variable at a time and compare a full profile under consistent light.
How to prevent it
- Calculate the reciprocator setting from conveyor speed, gun count and gun spacing.
- Stagger the spray paths so coverage is even rather than overlapped.
- Retain the approved line setting for the specific profile and low-gloss finish.
- Check a first-off profile before continuing the run.
Quick answers
Frequently asked questions
Why do the bands look light and dark?
Uneven film build changes the gloss, and the surface then reflects light differently along the profile.
Can I set reciprocator speed by feel?
In our field experience, we recommend calculating it from conveyor speed, gun count and gun spacing rather than adjusting by feel.
Why are low-gloss profiles sensitive?
Their narrow gloss window makes small film-thickness differences easier to see.
This guide refers to the applicable GB/T requirements. The standard specifies a low-gloss tolerance of ±5 gloss units for gloss values from 3 to 30, measured at 60°. Use the project’s agreed inspection requirement.
Test the real finish
Send us your sample panel