Moreaco practical guide
Coating peeling off aluminium profiles — why isn't a dry test enough?
A dry cross-cut result does not show how the coating behaves after water reaches it. In one case we investigated, aluminium profile samples blistered after boiling and peeled off in sheets, exposing bright metal. Check pretreatment first, but do not name the failed step without retesting. Use dry, wet and boiling-water adhesion evidence together.
Moreaco is a powder coating manufacturer in Yunnan, China, specialising in custom and bonded metallic powder coatings.
Common causes
A dry-only acceptance check
The coating passes a dry cross-cut but has not been challenged after water exposure.
Pretreatment needs investigation
Pretreatment is the first area to check, but the failed step was not established.
No retained wet-test evidence
Without wet and boiling-water results, the failure can remain hidden until later use.
How to check
- Record the dry cross-cut result, but do not stop there.
- The standard specifies that for the wet check, cut the grid and soak it at about 38°C for 24 hours.
- The standard specifies that for the boiling-water check, cut the grid and boil it for 20 minutes.
- If blistering or sheet peeling appears, investigate pretreatment and retest before assigning a specific failed step.
How to prevent it
- Include dry, wet and boiling-water adhesion in the agreed acceptance plan.
- Keep the actual test conditions and result with the batch record.
- Control pretreatment and verify it with evidence rather than assumption.
- Do not accept a dry result as proof of water-exposure adhesion.
Quick answers
Frequently asked questions
Can a coating pass dry adhesion and still peel after water exposure?
Yes. Wet and boiling-water adhesion checks are needed in addition to the dry test.
Does peeling prove exactly which pretreatment step failed?
No. Pretreatment is the first area to investigate, but the exact failed step still requires retesting.
What did the samples look like after boiling?
The samples blistered and the coating peeled off in sheets, exposing bright metal.
This guide refers to the applicable GB/T aluminium profile adhesion requirements. Project acceptance must follow the agreed standard and test conditions.
Test the real finish
Send us your sample panel
Free sample panel, you only cover courier.